$ Electronic Data Sheet generated with HMS Anybus-S DP Development Tool $ EtherNet/IP Fieldbus DLL Ver. 01.04 [File] DescText = "ACS800 (PS200) Drive"; CreateDate = 10-14-2008; CreateTime = 12:01:01; ModDate = 10-14-2008; ModTime = 12:01:01; Revision = 1.2; HomeURL = "www.abb.us/drives"; [Device] VendCode = 46; VendName = "ABB Inc"; ProdType = 2; ProdTypeStr = "AC Drives"; ProdCode = 245; MajRev = 2; MinRev = 06; ProdName = "ACS800 (PS200) with RETA-01"; Icon = "PS200 ITT.ico"; [Device Classification] Class1 = EtherNetIP; [Port] Port1 = TCP, $ port type name "EtherNet/IP", $ name of port "20 F5 24 01", $ instance one of the TCP/IP interface object 2; $ port number $ There is a problem in RSNetWorx with unused Connection Manager connections. $ Connection Manager is not used by, for example, 1756 series, which may $ cause the program to crash. If it happens, you can try to delete the sections $ Params and Connection Manager in this file. [Params] Param1 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC7, $ data type : 16-bit Unsigned Integer 2, $ data size in bytes "Output Size", $ name "", $ units "", $ help string 0,64,4, $ min,max,default data values, 0,450,16, 0,0,0,0, $ mult,dev,base,offset scaling not used 0,0,0,0, $ mult,dev,base,offset link not used 0; $ decimal places not used Param2 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC7, $ data type : 16-bit Unsigned Integer 2, $ data size in bytes "Input Size", $ name "", $ units "", $ help string 4,68,8, $ min,max,default data values, 8,454,20, 0,0,0,0, $ mult,dev,base,offset scaling not used 0,0,0,0, $ mult,dev,base,offset link not used 0; Param3 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC6, $ data type : 8-bit Unsigned Char 1, $ data size in bytes "Consumer", $ name "", $ units "", $ help string 20,121,20, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used ; $Enum3 = 20, "20", 21, "21", 100, "100", 102, "102", 121, "121"; Param4 = 0, $ first field shall equal 0 ,, $ path size,path 0x0000, $ descriptor 0xC6, $ data type : 8-bit Unsigned Char 1, $ data size in bytes "Producer", $ name "", $ units "", $ help string 70,171,70, $ min,max,default data values ,,,, $ mult,dev,base,offset scaling not used ,,,, $ mult,dev,base,offset link not used ; $Enum4 = 70, "70", 71, "71", 101, "101", 103, "103", 121, "121"; [Connection Manager] Connection1 = 0x04010002, $ trigger & transport $ 0-15 = supported transport classes (class 1) $ 16 = cyclic (1 = supported) $ 17 = change of state (0 = not supported) $ 18 = on demand (0 = not supported) $ 19-23 = reserved (must be zero) $ 24-27 = exclusive owner $ 28-30 = reserved (must be zero) $ 31 = client 0 (don't care for classes 0 and 1) 0x44240405, $ point/multicast & priority & realtime format $ 0 = O=>T fixed (1 = supported) $ 1 = O=>T variable (0 = not supported) $ 2 = T=>O fixed (1 = supported) $ 3 = T=>O variable (0 = not supported) $ 4-7 = reserved (must be zero) $ 8-10 = O=>T header (4 byte run/idle) $ 11 = reserved (must be zero) $ 12-14 = T=>O header $ 15 = reserved (must be zero) $ 16-19 = O=>T point-to-point $ 20-23 = T=>O multicast $ 24-27 = O=>T scheduled $ 28-31 = T=>O scheduled ,Param1,, $ O=>T RPI,Size,Format ,Param2,, $ T=>O RPI,Size,Format ,, $ config part 1 (dynamic assemblies) ,, $ config part 2 (module configuration) "Discrete Exclusive Owner", $ connection name "", $ Help string "20 04 24 01 2C [Param3] 2C [Param4]"; $ exclusive output path $ End of Electronic Data Sheet